MSA ALTAIR 2X CI2 Gas Detector Charcoal
- $421.00
- Brands MSA Safety Works
- Product Code: 10154080
- Availability: In Stock
MSA Safety Works ALTAIR 2X Cl₂ Gas Detector – CharcoalProduct OverviewThe MSA Safety Works ALTAIR 2X Cl₂ is a compact personal gas detector designed to monitor chlorine (Cl₂) in workplace environments. This single-gas configuration is intended for applications where continuous personal monitoring of chlorine exposure is required.The detector features MSA sensor technology, a compact housing, and m..
Detects CI2 0.5–1 ppm for Accurate Industrial Monitoring
MSA Safety Works ALTAIR 2X Cl₂ Gas Detector – Charcoal
Product Overview
The MSA Safety Works ALTAIR 2X Cl₂ is a compact personal gas detector designed to monitor chlorine (Cl₂) in workplace environments. This single-gas configuration is intended for applications where continuous personal monitoring of chlorine exposure is required.
The detector features MSA sensor technology, a compact housing, and multiple alarm methods to help notify the wearer when the configured chlorine concentration reaches an alarm level.
This configuration has factory-set low and high alarms of 0.5 ppm and 1.0 ppm, respectively, and is supplied in a charcoal-colored housing.
Key Features
Single-gas chlorine (Cl₂) monitoring
Factory-set low alarm: 0.5 ppm
Factory-set high alarm: 1.0 ppm
Compact design for personal monitoring
Visual, audible, and vibration alarms
Easy-to-read display
Rugged housing designed for industrial environments
IP67-rated protection against dust and water
Replaceable sensor and battery design
Event and measurement data recording
Suitable for professional workplace gas-monitoring applications
Chlorine Detection Specifications
| Parameter | Specification |
|---|---|
| Gas Detected | Chlorine (Cl₂) |
| Sensor Type | Electrochemical |
| Low Alarm | 0.5 ppm |
| High Alarm | 1.0 ppm |
| Measurement Range | 0–10 ppm |
| Resolution | 0.1 ppm |
| Typical Response Time (T90) | <15 seconds |
The 0.5 ppm and 1.0 ppm values are alarm thresholds, rather than the full measurement capability of the sensor. The documented chlorine sensor range extends to approximately 10 ppm.
Product Specifications
| Specification | Details |
|---|---|
| Brand | MSA Safety Works |
| Product Family | ALTAIR 2X |
| Model | ALTAIR 2X Cl₂ |
| Gas Configuration | Cl₂ |
| Gas Monitored | Chlorine |
| Low Alarm | 0.5 ppm |
| High Alarm | 1.0 ppm |
| Measurement Range | 0–10 ppm |
| Resolution | 0.1 ppm |
| Sensor Technology | Electrochemical |
| Display | Digital display |
| Alarm Types | Visual, audible, and vibration |
| Housing Color | Charcoal |
| Ingress Protection | IP67 |
| Device Type | Portable personal gas detector |
Alarm and Notification System
The ALTAIR 2X is designed to provide several types of warnings when the detected chlorine concentration reaches a programmed alarm level.
Visual Alarm
Bright LED indicators provide a quick visual warning that can be seen during normal operation.
Audible Alarm
An audible alarm provides an additional warning when the instrument enters an alarm condition.
Vibration Alarm
The integrated vibration alert provides a tactile warning, which can be particularly useful in noisy work areas where an audible alarm may be difficult to notice.
The combination of visual, audible, and vibration alerts gives workers multiple ways to recognize a hazardous gas condition.
Compact Design for Personal Monitoring
The ALTAIR 2X platform is designed for workers who need a dedicated personal gas monitor without the size and complexity of a larger multi-gas instrument.
Its compact form factor allows the detector to be carried or worn during routine work, inspections, maintenance, and other activities where chlorine exposure could occur.
The IP67 protection rating helps protect the instrument against dust and water ingress under the applicable test conditions.
Typical Applications
The chlorine version of the ALTAIR 2X may be suitable for workplaces and operations where chlorine exposure is a potential hazard, including:
Water and wastewater treatment
Chemical processing
Industrial manufacturing
Plant maintenance
Utilities
Chemical storage and handling
Emergency response
Maintenance and turnaround operations
General industrial environments
The suitability of the detector for a particular workplace should always be determined through the site's hazard assessment and applicable safety requirements.
Maintenance and Operation
For reliable gas monitoring, the detector should be properly maintained throughout its service life. Routine procedures may include:
Visual inspection before use
Functional or bump testing as required
Calibration according to MSA's recommendations
Sensor and battery replacement when necessary
Review of alarm and instrument status
Periodic maintenance according to the applicable service schedule
The ALTAIR 2X platform also supports event and measurement data recording, which can help organizations maintain records associated with instrument use.
Important Safety Information
The ALTAIR 2X Cl₂ is a professional gas-monitoring instrument and should be used according to the manufacturer's operating instructions, applicable approvals, and workplace safety procedures.
The 0.5 ppm low alarm and 1.0 ppm high alarm are configured alarm thresholds and should not be confused with the sensor's complete measurement range.
Always verify the actual detector's approval markings, sensor configuration, calibration requirements, and operating limitations before using it in a hazardous location.
A personal gas detector should be considered one component of a complete workplace gas-detection and safety program and should not be used as the sole protective measure.
Summary
The MSA Safety Works ALTAIR 2X Cl₂ Gas Detector is a compact personal monitor designed specifically for chlorine detection. With factory-set 0.5 ppm and 1.0 ppm alarm levels, electrochemical sensing, multiple alarm indicators, and rugged IP67 protection, it provides a practical solution for workers who require personal chlorine monitoring.
Quick Specifications
Gas: Chlorine (Cl₂)
Low Alarm: 0.5 ppm
High Alarm: 1.0 ppm
Measurement Range: 0–10 ppm
Resolution: 0.1 ppm
Sensor: Electrochemical
Color: Charcoal
Protection: IP67
Alarm: Visual, audible, and vibration