Login or create an account
CloseReturning Customer
I am a returning customer
Login or create an account
CloseRegister Account
If you already have an account with us, please login at the login form.
Your Account Has Been Created!
Thank you for registering with Juna Tools!
You will be notified by e-mail once your account has been activated by the store owner.
If you have ANY questions about the operation of this online shop, please contact the store owner.
Account Logout
You have been logged off your account. It is now safe to leave the computer.
Your shopping cart has been saved, the items inside it will be restored whenever you log back into your account.
Generac 5500 Watt Diesel Generator
- $1,647.00
- Brands Generac
- Product Code: 6864
- Availability: In Stock
Generac 5,500-Watt Diesel-Fueled 50-State Portable GeneratorThe Generac 5,500-Watt Diesel-Fueled 50-State Portable Generator is designed to provide dependable portable power for demanding work environments, emergency situations, and temporary electrical needs. Its diesel-fueled engine makes it a practical option for users who prefer diesel power for jobsite and commercial applications.With a 5,500..
Key Features of the 5500W Diesel Generator
Generac 5,500-Watt Diesel-Fueled 50-State Portable Generator
The Generac 5,500-Watt Diesel-Fueled 50-State Portable Generator is designed to provide dependable portable power for demanding work environments, emergency situations, and temporary electrical needs. Its diesel-fueled engine makes it a practical option for users who prefer diesel power for jobsite and commercial applications.
With a 5,500-watt output rating, this generator can provide electricity for a range of compatible tools, appliances, equipment, and other electrical loads. Its portable configuration allows it to be transported to locations where utility power is unavailable.
Key Features
5,500-watt power output for a variety of portable applications.
Diesel-fueled engine designed for dependable power generation.
50-state configuration for broad U.S. availability.
Portable design for jobsites, emergency use, maintenance, and outdoor applications.
Suitable for compatible power tools, equipment, appliances, and temporary electrical loads.
Diesel fuel can be practical for users already operating diesel-powered equipment.
Designed for temporary power rather than permanent standby installation.
5,500-Watt Power Output
The generator provides 5,500 watts of rated power, offering useful capacity for a range of electrical equipment.
When connecting multiple devices, the total electrical demand should remain within the generator's rated output. Equipment with motors, compressors, pumps, or other inductive loads may require additional power during startup.
Before operation, calculate both the starting and running requirements of connected equipment to ensure the generator can safely handle the combined load.
Diesel-Fueled Operation
The generator uses diesel fuel, making it particularly suitable for users who need a portable generator that operates on a fuel commonly used in commercial vehicles, machinery, and equipment.
Diesel fuel can be advantageous for certain worksite applications where diesel is already readily available. Proper fuel storage and handling are essential for reliable operation.
For best performance:
Use the diesel fuel grade specified by Generac.
Keep fuel clean and free from water or contamination.
Refuel only with the generator shut down and sufficiently cool.
Store diesel in appropriate approved containers or tanks.
Follow the manufacturer's recommendations for long-term storage.
Perform regular fuel-system inspections and maintenance.
Actual fuel consumption and runtime vary according to electrical load, fuel condition, ambient temperature, altitude, and operating conditions.
Portable Power for Jobsites
The portable design allows the generator to be transported to locations where permanent electrical service is unavailable.
Potential applications include:
Construction jobsites
Contractor work
Maintenance operations
Workshops
Property projects
Emergency power
Outdoor work
Temporary electrical service
Equipment servicing
Its diesel-fueled configuration can be especially practical for professional users who already maintain diesel fuel for other equipment.
Emergency Backup Applications
The generator can provide temporary electricity during utility outages or other power interruptions.
Depending on the connected load, it may be used to power selected:
Refrigerators
Freezers
Pumps
Lighting
Power tools
Workshop equipment
Small appliances
Other compatible electrical devices
As a portable generator, it should not be connected directly to permanent household wiring unless an appropriately rated transfer system has been installed by a qualified electrician.
50-State Configuration
This model is identified as a 50-state generator, making it designed for broad U.S. availability.
Local regulations may still apply to generator operation, emissions, noise, fuel storage, electrical connections, and placement. Users should verify applicable requirements for their specific location and application.
Product Specifications
| Specification | Details |
|---|---|
| Brand | Generac |
| Product Type | Portable Generator |
| Fuel Type | Diesel |
| Power Output | 5,500 W |
| Generator Configuration | Portable |
| Emissions Configuration | 50-State |
| Primary Applications | Jobsite, Emergency, Maintenance & Temporary Power |
| Installation Type | Portable / Temporary Use |
Specification note: Exact technical details such as starting/surge watts, continuous output, engine manufacturer and model, engine displacement, fuel-tank capacity, estimated runtime, voltage, frequency, receptacle configuration, circuit-breaker ratings, dimensions, weight, noise level, wheel and handle configuration, and warranty should be verified against the exact Generac model number. These specifications can vary by generator configuration.
Benefits at a Glance
5,500-Watt Output
Provides useful electrical capacity for compatible tools, appliances, and equipment.
Diesel Fuel
Offers a practical fuel option for professional users and worksites where diesel is already in use.
Portable Configuration
Can be transported to locations requiring temporary electricity.
50-State Model
Designed for broad U.S. availability, subject to applicable local regulations.
Versatile Applications
Suitable for construction, maintenance, emergency backup, workshops, outdoor projects, and temporary power needs.
Safe Operating Practices
A diesel generator produces exhaust gases, including carbon monoxide, and must never be operated inside a home, garage, basement, shed, tent, or other enclosed or partially enclosed area.
Always:
Operate the generator outdoors in a well-ventilated location.
Keep exhaust directed away from buildings, doors, windows, vents, and occupied areas.
Keep the generator dry and protected from direct water exposure.
Use properly rated electrical cords and accessories.
Do not overload the generator.
Shut the generator down and allow it to cool before refueling.
Keep diesel fuel away from ignition sources.
Follow all safety warnings and instructions supplied by Generac.
Maintenance
Routine maintenance is important for diesel-engine reliability, particularly when the generator is used for extended periods or stored for emergency use.
Depending on the exact model, maintenance may include:
Engine-oil inspection and replacement
Air-filter service
Fuel-filter service
Fuel-system inspection
Battery or starting-system checks, where applicable
Cooling-system inspection
Electrical connection checks
General engine inspection
Always follow the maintenance schedule specified in the owner's manual for the exact generator model.
A Dependable Diesel Portable Power Solution
The Generac 5,500-Watt Diesel-Fueled 50-State Portable Generator provides a practical combination of portable power, diesel-fueled operation, and broad U.S. availability.
With its 5,500-watt output, diesel engine, portable configuration, and 50-state designation, it is well suited to contractors, maintenance professionals, property owners, and other users who need reliable temporary electrical power for jobsites, emergency situations, outdoor work, and equipment applications.
